2001
The relation between fungal propagules in indoor air and home characteristics
Ren P, Jankun T, Belanger K, Bracken M, Leaderer B. The relation between fungal propagules in indoor air and home characteristics. Allergy 2001, 56: 419-424. PMID: 11350305, DOI: 10.1034/j.1398-9995.2001.056005419.x.Peer-Reviewed Original ResearchMeSH KeywordsAir MicrobiologyAir Pollution, IndoorAnimalsAnimals, DomesticAsthmaCatsEnvironmental MonitoringEpidemiological MonitoringFamily CharacteristicsFungiHeatingHousingHumansHumidityIncomeInfantNew EnglandPredictive Value of TestsProspective StudiesSeasonsSurveys and QuestionnairesTime FactorsVentilationConceptsCFU/m3 airInfants' bedroomsMain living areaProspective cohort studyDevelopment of asthmaHome characteristicsAnnual household incomeAllergen exposureCohort studyEpidemiologic studiesM3 airPresence of petsExposure levelsExposure assessmentSignificant differencesBurkard portable air samplerLiving areasQuestionnaireIndoor airFungal exposure assessmentHouse characteristicsHousehold incomeHomeDG-18Asthma
1995
EXPOSURE TO ELECTROMAGNETIC FIELDS DURING PREGNANCY WITH EMPHASIS ON ELECTRICALLY HEATED BEDS
Bracken M, Belanger K, Hellenbrand K, Dlugosz L, Holford T, McSharry J, Addesso K, Leaderer B. EXPOSURE TO ELECTROMAGNETIC FIELDS DURING PREGNANCY WITH EMPHASIS ON ELECTRICALLY HEATED BEDS. Epidemiology 1995, 6: 263-270. PMID: 7619934, DOI: 10.1097/00001648-199505000-00013.Peer-Reviewed Original ResearchConceptsFetal growth retardationGrowth retardationBed useIntrauterine growth retardationVideo display terminal useDose-response relationPersonal monitorsEMF exposureTime-weighted analysisMonitoring of exposureThird trimesterProspective studyFetal growthWire codesHome measurementsReproductive outcomesHuman studiesPregnancyStudy designVideo display terminalsExposure measuresHours of useMeaningful increaseRiskExposure
1992
Congental Defects and Electric Bed Heating in New York State: A Register-based Case-Control Study
Dlugosz L, Vena J, Byers T, Sever L, Bracken M, Marshall E. Congental Defects and Electric Bed Heating in New York State: A Register-based Case-Control Study. American Journal Of Epidemiology 1992, 135: 1000-1011. PMID: 1595686, DOI: 10.1093/oxfordjournals.aje.a116394.Peer-Reviewed Original ResearchMeSH KeywordsAdultBedsCase-Control StudiesCleft LipCleft PalateConfidence IntervalsConfounding Factors, EpidemiologicEducational StatusElectricityEmploymentFemaleFeverHeatingHumansInfant, NewbornMaleMaternal AgeNeural Tube DefectsNew YorkOdds RatioParityRacial GroupsRegistriesResidence CharacteristicsRisk FactorsSex FactorsSmokingSurveys and QuestionnairesVitaminsConceptsCase-control studyCleft palateOdds ratioCleft lipCongenital defectsOral cleft defectsRespective odds ratiosNew York State Congenital Malformations RegistryConfidence intervalsElectric blanket usePotential confounding factorsCongenital Malformations RegistryNeural tube defectsOdds ratio estimatesElectric blanketHeated waterbedsNew York residentsSeason of conceptionLast mensesRisk factorsChildhood cancerMaternal raceCleft defectsConfounding factorsMalformations Registry